This section provides technical specifications for Supermicro 1014S node types.

Supermicro 1014S 240 TB (General Purpose) Supermicro 1014S 216 TB (General Purpose) Supermicro 1014S 96 TB (General Purpose) Supermicro 1014S 240 TB (Active) Supermicro 1014S 216 TB (Active) Supermicro 1014S 96 TB (Active)
Connectivity Ports (NIC) 2 × 25 GbE (1 × Mellanox ConnectX-4 Lx NIC)
or 2 × 25 GbE (1 × SMC AOC-S25G-b2S NIC)
2 × 100 GbE (1 × Mellanox ConnectX-6 NIC)
or 2 × 100 GbE (1 × SMC AOC-S100G-b2C NIC)
Management Ports (BMC) 1 × 1 GbE Base-T (RJ45)
Solid State Storage Media (Cache) 4 × 1.92 TB NVMe
or 4 × 3.84 TB NVMe
or 4 × 7.68 TB NVMe
4 × 960 GB NVMe
or 4 × 1.92 TB NVMe
or 4 × 3.84 TB NVMe
4 × 1.92 TB NVMe
or 4 × 3.84 TB NVMe
or 4 × 7.68 TB NVMe
4 × 960 GB NVMe
or 4 × 1.92 TB NVMe
or 4 × 3.84 TB NVMe
HDD Storage Media 12 × 20 TB 12 × 18 TB 12 × 8 TB 12 × 20 TB 12 × 18 TB 12 × 8 TB
Boot Drive 1 × 960 GB M.2 NVMe
CPU AMD EPYC 7232P 8-Core Processor
or AMD EPYC 7313P 16-Core Processor
Memory 96 GB (6 GB × 16)
Power Supply 2 × 750 W Power Supplies
Dimensions (H × W × D) 1.7" × 17.6" × 37" (43 mm × 447 mm × 940 mm)
Weight 39.5 lbs (17.5 kg)
Power Requirements 100–240 V, 50/60 Hz
Typical Power Consumption 1.12 A @ 240 V
(2.44 A @ 110 V)
1.10 A @ 240 V
(2.39 A @ 110 V)
1.17 A @ 240 V
(2.55 A @ 110 V)
1.20 A @ 240 V
(2.62 A @ 110 V)
1.18 A @ 240 V
(2.56 A @ 110 V)
1.25 A @ 240 V
(2.74 A @ 110 V)
Typical Thermal Rating 268 W (VA)
(914 BTU/hr)
263 W (VA)
(897 BTU/hr)
280 W (VA)
(955 BTU/hr)
288 W (VA)
(983 BTU/hr)
282 W (VA)
(962 BTU/hr)
301 W (VA)
(1028 BTU/hr)
Maximum Power Consumption
1.23 A @ 240 V
(2.67 A @ 110 V)
1.20 A @ 240 V
(2.62 A @ 110 V)
1.24 A @ 240 V
(2.71 A @ 110 V)
1.35 A @ 240 V
(2.94 A @ 110 V)
1.32 A @ 240 V
(2.88 A @ 110 V)
1.36 A @ 240 V
(2.97 A @ 110 V)
Maximum Thermal Rating 294 W (VA)
(1003 BTU/hr)
288 W (VA)
(982 BTU/hr)
298 W (VA)
(1017 BTU/hr)
323 W (VA)
(1102 BTU/hr)
317 W (VA)
(1081 BTU/hr)
327 W (VA)
(1116 BTU/hr)
Operating Temperature 50°F–95°F (10°C–35°C)
Non-Operating Temperature -40°F–140°F (-40°C–60°C)
Operating Relative Humidity 8%–90% (non-condensing)
Non-Operating Relative Humidity
5%–95% (non-condensing)