Procedure for safely identifying and replacing a failed drive on Quiver Arrow platforms running Qumulo Core.

Drives in Qumulo clusters are hot-swappable. You can replace a failed drive without taking the node offline.

  1. Identify the failed drive using the Qumulo Web UI or the qq cluster_slots command. Note the node, drive bay, and drive serial number reported.

  2. Locate the failed drive in the chassis at the drive bay you noted on the indicated node.

  3. Confirm you have the right drive:

    • Check for the amber fault LED on the drive carrier.
    • Verify the drive serial number on the carrier matches the one you noted from Qumulo.
    • If unsure, contact the Qumulo Care Team before removing any drive.
  4. Remove the failed drive.

  5. Insert the replacement drive.

  6. Qumulo Core automatically detects and incorporates the new drive, then begins the reprotect process. Progress can be monitored from the Qumulo Web UI or with the qq restriper_status command.