Important
The C-192T, C-432T, and K-432T platforms reached their End of Availability on May 9, 2025. End of Platform Support (EoPS) is May 9, 2030.
The C-192T, C-432T, and K-432T platforms reached their End of Availability on May 9, 2025. End of Platform Support (EoPS) is May 9, 2030.
Note
This page is reference material (drive bay layout) for the C-192T, C-432T, and K-432T platforms. For replacement procedures, see Replacing Hardware Components and Replacing the Chassis.
This page is reference material (drive bay layout) for the C-192T, C-432T, and K-432T platforms. For replacement procedures, see Replacing Hardware Components and Replacing the Chassis.
This page provides drive bay mapping for the C-192T, C-432T, and K-432T (Q2U_1 platform).
HDD Drawers (24 bays across 3 drawers)
The chassis contains 24 HDDs across three top-load drawers, labeled in sequence from top to bottom.
Caution
When the HDD drawer is full, it is very heavy. Adding extra weight (such as resting tools on the drawer) can cause the rails to deform.
When the HDD drawer is full, it is very heavy. Adding extra weight (such as resting tools on the drawer) can cause the rails to deform.
Top Tray (Drawer 1)
BACK of server
+----------+----------+----------+----------+
| Bay 1 | Bay 2 | Bay 3 | Bay 4 |
+----------+----------+----------+----------+
| Bay 5 | Bay 6 | Bay 7 | Bay 8 |
+----------+----------+----------+----------+
FRONT of server
Middle Tray (Drawer 2)
BACK of server
+----------+----------+----------+----------+
| Bay 9 | Bay 10 | Bay 11 | Bay 12 |
+----------+----------+----------+----------+
| Bay 13 | Bay 14 | Bay 15 | Bay 16 |
+----------+----------+----------+----------+
FRONT of server
Bottom Tray (Drawer 3)
BACK of server
+----------+----------+----------+----------+
| Bay 17 | Bay 18 | Bay 19 | Bay 20 |
+----------+----------+----------+----------+
| Bay 21 | Bay 22 | Bay 23 | Bay 24 |
+----------+----------+----------+----------+
FRONT of server
Rear NVMe Drives
The rear NVMe drives are located at the back of the chassis in a 2 × 3 configuration.
+---------+---------+---------+
| NVMe 25 | NVMe 26 | NVMe 27 |
+---------+---------+---------+
| NVMe 28 | NVMe 29 | NVMe 30 |
+---------+---------+---------+
NIC Ports
The Qumulo C-series platform uses a networking configuration where both back-end and front-end traffic are handled by the same NIC. Each node has 2 NIC ports on the rear of the chassis (plus a separate IPMI port).
NIC card (rear)
+---------+
| Port 1 | <- top
+---------+
| Port 2 | <- bottom
+---------+
Linux interface names depend on NIC manufacturer:
| NIC Manufacturer | Port Location | Port Label |
|---|---|---|
| Mellanox | Top | 1 (eth3) |
| Mellanox | Bottom | 2 (eth4) |
| Broadcom | Top | 1 (eth0) |
| Broadcom | Bottom | 2 (eth1) |
Caution
Don’t use the LAN On Motherboard ports. Only use the external NIC ports for connections.
Don’t use the LAN On Motherboard ports. Only use the external NIC ports for connections.
Note
For reliability, both ports on each node should be connected. If a single connection fails, the node will be unavailable.
For reliability, both ports on each node should be connected. If a single connection fails, the node will be unavailable.
Boot Drive
The boot drive is an internal M.2 SSD located on the motherboard.
Caution
Before removing the boot drive, contact the Qumulo Care team for detailed instructions on how to proceed.