This section provides technical specifications for Quiver 1U Hybrid Gen2 node types.
Note
- On hybrid platforms, SSDs act as a cache. You can determine the size of these drives in either of the following ways:
- Physically examine the SSD drive.
- In the Qumulo Core Web UI, click Cluster > Overview, then click one of the node names in the table. The SSD drive size is listed on the node detail page.
- For this platform, all models ship without NICs.
Quiver 1U Hybrid Gen2 240 TB (General Purpose) | Quiver 1U Hybrid Gen2 240 TB (Active) | Quiver 1U Hybrid Gen2 96 TB (Active) | |
---|---|---|---|
Connectivity Ports (NIC) | 2 × 25 GbE (1 × Mellanox ConnectX-4 Lx NIC) or 2 × 25 GbE (1 × Broadcom P225P NIC) |
2 × 100 GbE (1 × Mellanox ConnectX-5 Lx NIC) or 2 × 100 GbE (1 × Broadcom P2100G NIC) |
2 × 25 GbE (1 × Mellanox ConnectX-4 Lx NIC) or 2 × 25 GbE (1 × Broadcom P225P NIC) or 2 × 100 GbE (1 × Mellanox ConnectX-5 Lx NIC) or 2 × 100 GbE (1 × Broadcom P2100G NIC) |
Management Ports (BMC) | 1 × 1 GbE Base-T (RJ45) | ||
Solid State Storage Media (Cache) | 4 × 1.92 TB NVMe or 4 × 3.84 TB NVMe or 4 × 7.68 TB NVMe |
4 × 960 GB NVMe or 4 × 1.92 TB NVMe or 4 × 3.84 TB NVMe |
|
HDD Storage Media | 12 × 20 TB | 12 × 8 TB | |
Boot Drive | 1 × 240 GB M.2 SATA | ||
CPU | 2 × Intel Xeon Bronze 3204 CPU @ 1.90GHz | 2 × Intel Xeon Silver 4210 CPU @ 2.20GHz | |
Memory | 64 GB (16 GB × 4) | 96 GB (16 GB × 6) | |
Power Supply | 2 × 700 W Power Supplies | ||
Dimensions (H × W × D) | 1.7" × 17.6" × 34.7" (43.2 mm × 448 mm × 881 mm) | ||
Weight | 66 lbs (30 kg) | ||
Power Requirements | 90–264 V, 47/63 Hz | ||
Typical Power Consumption | 1.62 A @ 240 V (3.54 A @ 110 V) |
1.6 A @ 240 V (3.5 A @ 110 V) |
|
Typical Thermal Rating | 389 W (VA) (1,327 BTU/hr) |
385 W (VA) (1,313 BTU/hr) |
|
Maximum Power Consumption |
1.72 A @ 240 V (3.75 A @ 110 V) |
1.84 A @ 240 V (4.0 A @ 110 V) |
1.95 A @ 240 V (4.26 A @ 110 V) |
Maximum Thermal Rating | 413 W (VA) (1,409 BTU/hr) |
441 W (VA) (1,505 BTU/hr) |
469 W (VA) (1,600 BTU/hr) |
Operating Temperature | 41°F–95°F (5°C–35°C) | ||
Non-Operating Temperature | -40°F–158°F (-40°C–70°C) | ||
Operating Relative Humidity | 20%–85% (non-condensing) | ||
Non-Operating Relative Humidity |
10%–95% (non-condensing) |